The role of axial flow fans and centrifugal fans in grain storage ventilation

Due to the significant temperature difference between air and grain, the first ventilation should be conducted during the day to minimize this difference and reduce condensation. Subsequent ventilation should ideally be done at night, as the primary goal of this ventilation is cooling. Nighttime air humidity is relatively high while temperatures are lower, minimizing moisture loss and maximizing cooling efficiency.

 

Initially, centrifugal fans may cause condensation on doors, windows, walls, and even the surface of the grain. Simply stop the fans, open the windows, turn on the axial flow fans, and, if necessary, turn the grain surface to expel the hot, humid air. Slow ventilation with axial flow fans will not cause condensation; only a slow decrease in the temperature of the upper and middle layers of grain will occur, with the temperature settling steadily as ventilation continues.

 

When using axial flow fans for slow ventilation, due to the small airflow and the fact that grain is a poor conductor of heat, some areas may experience slow ventilation initially. However, as ventilation continues, the overall grain temperature will gradually stabilize.

 

Grains that require slow ventilation must be cleaned by a vibrating screen, and the impurity areas caused by automatic grading must be cleaned up in a timely manner after the grains are put into the warehouse; otherwise, uneven local ventilation may occur.